Telescope Collimation
Learn when telescope collimation is needed, which adjustments belong to your exact model and how to check alignment without turning the wrong screw.

Collimation aligns the optical parts. First identify the exact telescope and read its manual. Use only the adjustments it names, make small changes and verify the view before doing more.
On this page
Telescope collimation means aligning the optical parts so that they work along the intended path. Some reflectors need user checks and adjustments. Other designs need a different method or maker service. Identify your telescope before reaching for a tool.
Start with the exact model's manual. Confirm that collimation is a user task for that instrument. Work in good light with the tube in the maker's stated position. Use only named adjustment points and a suitable checking tool. Verify each stage before moving to the next. Stop if you cannot identify a screw's purpose.
Does your telescope need collimation?
A soft image does not prove bad alignment. Check focus, eyepiece seating and the steadiness of the mount first. Look for dew or fog. Let the telescope settle as the manual advises. Moving air can make a sharp planet look soft even when the optics are aligned.
Newtonian reflectors commonly have a user alignment method for their mirrors. Refractors usually do not use that same routine. Compound designs can have their own checks and adjustment limits. Do not apply a Newtonian video to an instrument with a different optical path.
Use the maker's product page to find the correct manual and model revision. For example, the Heritage 150 product page identifies a reflector; it does not make every screw on the tube a user alignment control. Match the manual to the telescope in front of you.
Prepare before telescope collimation
Choose a clear, well-lit place and put small tools where they cannot fall into the tube. Follow the maker's tube position and cap instructions. Keep hands and tools away from optical surfaces. Do not use the main mirror as a place to rest anything.
Identify the focuser, the secondary mirror holder and the primary mirror cell. Then identify the actual adjustment and locking controls from the manual. A retaining screw can hold a part in place rather than align it. Loosening the wrong one can damage the instrument.
Check that the recommended collimation cap or other tool seats squarely in the focuser. A tilted tool gives a misleading view. If you use a laser tool, follow its instructions and keep the beam away from eyes. A laser reading is only useful if the tool itself is correctly aligned and seated.
Follow the model's sequence
For a Newtonian, the manual's checks may address the position of the secondary, its tilt and the primary mirror tilt. These are different tasks. Do not turn all the controls at once because the patterns look unfamiliar.
Make one small adjustment, then look again. Keep track of the control you moved and what the view did. If it moves the wrong feature, return to the last known setting and reread the step. Do not keep turning in the hope that the rings will eventually look right.
Keep adjustment and locking steps in the maker's order. A lock can alter the reading as it tightens. Check again after securing it. Leave the system in a mechanically safe state rather than ending with a loose mirror cell because the tool pattern looked centered.
The exact geometry and hardware differ. The useful rule is to identify the model, follow its order and verify each adjustment. Sky-Watcher's manual library is a source for its instruments; use the relevant maker for another brand.
Verify the result on the sky
After the indoor check, use a suitable star when conditions allow. Follow the manual's star-check method and keep the star centered as directed. A view near the field edge can mislead. Use a steady mount so movement does not hide the pattern.
Allow for air motion and focus. A boiling image is a poor basis for fine adjustment. If the conditions are bad, keep the completed mechanical check and return on a better night. Do not chase a constantly changing pattern with more screw turns.
Record the tool and sequence in your own observing log. If the telescope often loses alignment, check how it is carried and whether the maker names a mechanical fault to inspect. Do not add homemade glue, springs or shims without a documented reason and method.
FAQ
Should I collimate every telescope?
No. First check the exact design and manual. A user-adjustable reflector and a sealed optical system may need very different care. A soft view can come from focus, air or dew. Confirm the cause before adjusting. Do not treat every visible screw as a collimation control.
Is a laser enough to prove alignment?
Only when it is a suitable tool for the telescope and is correctly aligned and seated. Follow both manuals. A laser that tilts in the focuser can point you toward the wrong adjustment. Use the maker's final verification method rather than relying on one reading alone.
Can I clean the mirror while doing this?
Collimation and cleaning are separate tasks. Dust on a mirror does not automatically require cleaning, and touching the surface can cause damage. Keep the adjustment job limited to the manual's steps. If cleaning is needed, follow the maker's specific method instead of adding it to the alignment routine.
When should I stop adjusting?
Stop when you cannot identify the control, when a part feels loose or when the expected pattern does not match the manual. Return to the last safe known state where possible. Ask the maker about the model and fault before opening or loosening parts beyond the user procedure.
Read next
Check alignment with the right method
Telescope collimation is a model-specific alignment task. Correct identification and small verified steps matter more than speed. Check ordinary causes of blur first, follow the exact manual and leave unfamiliar retaining hardware alone.